The EM Academy PIERS Home PIERS Online Home · ISSN: 1931-7360
PIERS Online
Home | Technical Committee | Author Login | Reviewer Login | New Submission | Advance Search
PIERS Online
Quick Article Search:


 
Vol. 5 - No. 8 - 2009
Vol. 5 - No. 7 - 2009
Vol. 5 - No. 6 - 2009
Vol. 5 - No. 5 - 2009
Vol. 5 - No. 4 - 2009
Vol. 5 - No. 3 - 2009
Vol. 5 - No. 2 - 2009
Vol. 5 - No. 1 - 2009
Vol. 4 - No. 8 - 2008
Vol. 4 - No. 7 - 2008
Vol. 4 - No. 6 - 2008
Vol. 4 - No. 5 - 2008
Vol. 4 - No. 4 - 2008
Vol. 4 - No. 3 - 2008
Vol. 4 - No. 2 - 2008
Vol. 4 - No. 1 - 2008
Vol. 3 - No. 8 - 2007
Vol. 3 - No. 7 - 2007
Vol. 3 - No. 6 - 2007
Vol. 3 - No. 5 - 2007
Vol. 3 - No. 4 - 2007
Vol. 3 - No. 3 - 2007
Vol. 3 - No. 2 - 2007
Vol. 3 - No. 1 - 2007
Vol. 2 - No. 6 - 2006
Vol. 2 - No. 5 - 2006
Vol. 2 - No. 4 - 2006
Vol. 2 - No. 3 - 2006
Vol. 2 - No. 2 - 2006
Vol. 2 - No. 1 - 2006
Vol. 1 - No. 6 - 2005
Vol. 1 - No. 5 - 2005
Vol. 1 - No. 4 - 2005
Vol. 1 - No. 3 - 2005
Vol. 1 - No. 2 - 2005
Vol. 1 - No. 1 - 2005
 
  PIERS Online Vol. 3 No. 6 2007 pp: 900-904

Design and Analysis of the Novel Test Tube Magnet for Portable NMR Device

Jizhong Chen, Yiming Zhang, and Jijun Xiao

doi:10.2529/PIERS060907042202

[PDF Full Text (594 KB)]
Downloads: 1571

Abstract:

The paper presents a novel test tube magnet (TTM) for Portable NMR device, which is composed of a dipole cylinder magnet and a hemi-cylinder or a hemi-sphere magnet. The hemi-cylinder or the hemi-sphere magnet is attached to one end of the dipole cylinder magnet, so that the whole magnet is shaped like a test tube. TTM generates a wide diameter spherical volume (DSV) with a high magnetic field homogeneity, which makes the device more applicable for portable NMR. The two configurations were simulated with three-dimensional finite-element methods. Flux density elements are effectively corrected in the DSV. The homogeneity increases, the magnet volumes and mass are markedly decreased, and the construction is very reasonable. Taken together the new designs have improved characteristics for portable NMR.

References:

1. Halbach, K., "Design of permanent multipole magnets with oriented rare earth cobalt materials," Nuclear Instruments and Methods, Vol. 169, 1-10, 1980.
doi:10.1016/0029-554X(80)90094-4

2. Furlani, E. P., S. Reznik, and W. Janson, "A three-dimensional field solution for bipolar cylinders," IEEE Trans. Magn., Vol. 30, No. 5, Sept., 1994.

3. Furlani, E. P., S. Reznik, and A. Kroll, "A three-dimensional field solution for radically polarized cylinders," IEEE Trans. Magn., Vol. 31, No. 1, Jan., 1995.
doi:10.1109/20.364587

4. Raich, H. and P. Blumler, "Design and construction of a Dipolar Halbach array with a uniformity field from identical bar magnets," NMR Mandhalas Concepts in Magnetic Resonance Part B(Magnetic Resonance Engineering), Vol. 23B, No. 1, 16-25, 2004.
doi:10.1002/cmr.b.20018

5. Hu, Z., "The research of improvement permanent magic ring," The Master Paper of IEE. CAS

© Copyright 2008 PIERS. All Rights Reserved.